Changes in Cough Airflow and Acoustics After Injection Laryngoplasty.

TitleChanges in Cough Airflow and Acoustics After Injection Laryngoplasty.
Publication TypeJournal Article
Year of Publication2022
AuthorsRameau A, Andreadis K, German A, Lachs MS, Rosen TE, Pitzrick MS, Symes LB, Klinck H
JournalLaryngoscope
Date Published2022 Jun 20
ISSN1531-4995
Abstract

OBJECTIVE/HYPOTHESIS: We explored the following hypotheses in a cohort of patients undergoing injection laryngoplasty: (1) glottic insufficiency affects voluntary cough airflow dynamics and restoring glottic competence may improve parameters of cough strength, (2) cough strength can be inferred from cough acoustic signal, and (3) glottic competence changes cough sounds and correlates with spectrogram morphology.

STUDY TYPE/DESIGN: Prospective interventional study.

METHODS: Subjects with glottic insufficiency secondary to unilateral vocal fold paresis, paralysis, or atrophy, and scheduled for injection laryngoplasty completed an instrumental assessment of voluntary cough airflow using a pneumotachometer and a protocolized voluntary cough sound recording. A Wilcoxon signed-rank test was used to compare the differences between pre- and post-injection laryngoplasty in airflow and acoustic measures. A Spearman rank-order correlation was used to evaluate the association between airflow and acoustic cough measures.

RESULTS: Twenty-five patients (13F:12M, mean age 68.8) completed voluntary cough airflow measurements and 22 completed cough sound recordings. Following injection laryngoplasty, patients had a statistically significant decreased peak expiratory flow rise time (PEFRT) (mean change: -0.03 s, SD: 0.06, p = 0.04) and increased cough volume acceleration (mean change: 13.1 L/s2 , SD: 33.9, p = 0.03), suggesting improved cough effectiveness. Correlation of cough acoustic measures with airflow measures showed a weak relationship between PEFRT and acoustic energy (coefficient: -0.31, p = 0.04) and peak power density (coefficient: -0.35, p = 0.02).

CONCLUSIONS: Our study thus indicates that injection laryngoplasty may help avert aspiration in patients with glottic insufficiency by improving cough effectiveness and that improved cough airflow measures may be tracked with cough sounds.

LEVEL OF EVIDENCE: 3 Laryngoscope, 2022.

DOI10.1002/lary.30255
Alternate JournalLaryngoscope
PubMed ID35723533
Grant List / / AR was supported for this project by American Laryngological, Rhinological and Otological Society through a Triological Society Career Development Award. /
K76 AG054866 / AG / NIA NIH HHS / United States
/ / Delete this, it is redundant. /
K76 AG054866 / AG / NIA NIH HHS / United States

Mailing Address
New York-Presbyterian Hospital
Weill Cornell Medical Center
Department of Emergency Medicine
525 E. 68th St., Box 179
New York, NY 10065

Office of the Chair
Emergency Medicine
525 E. 68th St., M-130
New York, NY 10065
(212) 746-0780

Residency Office
530 E. 70th St., M-127
New York, NY 10021
(212) 746-0892
may2004@med.cornell.edu

Research Office
525 E. 68th St., M-130
New York, NY 10065
EMResearch@med.cornell.edu

Leading Emergency Care